High Voltage Labratory Overview

At present more than Eight hundred colleges provide engineering education in India . Approximately three hundred of them offer undergraduate programs in Electrical and Electronic Engineering that include High Voltage Engineering. It is mandatory as per the guidelines of the All India Council for Technical Education (AICTE) that the laboratory facilities are to be provided for the programs which are offered by the colleges. However, very few colleges have high voltage and High Power Laboratory facilities due to the involvement of huge costs and availability of specialised faculty members as well as skilled staffs in the field of High voltage and High Power Engineering.

The High Voltage Laboratory is a graduate research and undergraduate teaching laboratory with the following infrastructure and testing facilities.

Infastructure
Impulse voltage generator – 800 kV, 40
500 mm sphere gap for HV measurement
Impulse voltage divider (damped capacitive type) –800 kV
Digital impulse oscilloscope with software
300 kV AC power frequency HV testing transformer
AC Divider 300KV
Partial Discharge Measuring System
Coupling Capacitor
Vessel for Vacuum and Pressure
Measuring Sphere gap - 500mm
RIV Measuring Instrument
Operation with Information Communication Technology (ICT) of Impulse as well as AC test
system, an unique facility in India.
Capacitance and tan delta measurement
Resistivity meter
Leakage current tester
Tests

HV Impulse testing
HV Dry / Wet Power frequency testing
Capacitance and Tan delta measurement
Partial discharge measurement
Insulation Resistance
RIV, Corona measurement
HV Calibration, CT/PT Calibration

It specialises in the measurement and testing of equipment and components of Electric Power Engineering. Teaching in laboratories includes studying the breakdown of air under varying atmospheric conditions, especially moisture, varying supply voltage and under multiple insulation arrangements. They are particularly geared towards the use of live-line techniques for transmission and distribution system maintenance. Transformer insulation condition measurement is also a set laboratory exercise. Lectures in High Voltage are embodied into specific courses associated with Electric Power Engineering. NIT, Durgapur is having the above facilities towards the High Voltage testing, it will also meet the innovative course work, curriculum, research of the students and the testing needs of nearby utilities and industries providing the application of ICT, remote operation facilities.
A Remotely Operated High Voltage Laboratory For Impulse Voltage Testing
S. Karmakar, N. K. Roy, Andrew Nafalski , Pathik Kumbhakar

In electrical power engineering education, it is advisable for students to be acquainted in laboratory courses with practical high voltage engineering knowledge. Because of high cost for setting up a high voltage laboratory, the laboratory is a potential cost effective educational tool for all the institutions that offer such programs at undergraduate or postgraduate levels. The laboratory provides an opportunity to share the teaching resources in terms of personnel and facilities. It has the opportunity to support all the learning objectives of the traditional high voltage laboratory in a remote setup. This work reports on the development of an ICT-enabled remotely operated high voltage laboratory at the National Institute of Technology, Durgapur, India, for online control of generation, measurement and analysis of steady state and transient high voltage phenomena. In the field of education, the laboratory is a potential tool for all institutions that offer electrical power engineering programs at undergraduate and postgraduate levels. The students can access and familiarize themselves with operations of the laboratory for conducting experiments and for testing high voltage power apparatus by using a local area network (LAN) as well as through the Internet. This work explains the approaches developed at the laboratory for experimentation in remote impulse voltage testing and online report generation. The laboratory can also be used for commercial high voltage tests for industries and utilities.

Effect Of Ageing In Transformer Oil Using UV-Visible Spectrophotometeric Technique
S. Karmakar, N. K. Roy, Pathik Kumbhakar

In power systems, varieties of insulation materials are used to protect the high voltage power apparatus such as transformer, switchgear, current transformer, potential transformer etc. One of the most common liquid insulating materials used as a dielectric medium in transformers is the transformer oil. The transformer oil is degraded due to the combination of the ageing processes such as partial discharge (PDs), electrical arcing, and thermal ageing while it is under operation during its long period of service. In this work, the effects of different ageing processes on the optical absorption properties of insulating oil of a model transformer is studied using a UV-visible spectrophotometer diagnostic method which is presently becoming a popular method to identify the ageing of the insulating oil of high voltage transformers. It is found that the aged transformer oils exhibit optical absorption in 200– 400 nm wavelength regions. The optical quality of the transformer oil is mostly degraded due to PDs, and sharp and prominent absorption peaks appear at 293 nm,306 nm, and 324 nm wavelengths, for sample which is aged due to PDs. For other aged samples, the peak at 306 nm is absent and the optical absorption characteristics are almost similar to that of the new transformer oil.

Applying Grey Theory Prediction Model On The DGA Data Of The Transformer Oil And Using It For Fault Diagnosis
Anjali Chatterjee, N.K. Roy

The Non-Destructive Evaluation of Power transformer by monitoring various parameters, to predict its in-service behavior, is very much necessary for operating engineer to avoid catastrophic failures and costly outages. Dissolved Gas Analysis (DGA) is an important tool for transformer fault diagnosis. It is observed that the result of DGA doesn’t have a perceivable change over a short period. For less population of data availability grey modeling is used. To apply probability theory, statistics, and fuzzy systems, there is a requirement for a large number of data, then only conclusion or some inference can be drawn. The advantage of using the grey system theory is that, it gives a fair accuracy in predicting the volume of the gases, expected to be generated after some time period, using a small sample of data. In this paper we have done a comparative study on the predicted results obtained by different model of Grey theory mainly whitened model, connotation model and modified grey model. It is found that the error generated from the prediction by all the three model are within the limit of 15% which is acceptable. Additional by linear regression we are establishing a correlation between the key gases. This helps us to detect the abnormality of the situation and diagnose the type of fault. Additional this work deals with the study on the behavior of the gas dissolved in the oil which has undergone filtration and the one without filtration. Through graphical means it has been clearly shown that filtration at periodic interval will extend the life of the transformer. It has been shown that the rate of gas generation also plays an important role to detect an active fault.

Condition Monitoring of High Voltage Transformers using Fiber Bragg Grating Sensor
B. Sarkar, C. Koley, N.K. Roy, P. Kumbhakar

High voltage (HV) power apparatus determines the stability of any electrical power system. Failure of such apparatus is mainly due to damage of insulation normally caused by the Partial Discharge (PD). Therefore PD measurements are globally considered as most essential and favored testing procedure for most of the HV power apparatus. Online condition monitoring may help to take proper corrective action at proper time, which reduces unscheduled down time and can save money for electrical supply utilities. HV power transformers are being considered as heart of any electrical system and they have received much attention in recent years. In HV transformers, PD is one of the main reasons for degradation of insulation quality. Therefore its detection can provide early indication of the insulation failures of transformers. PD can be traced through direct measurement of current, electromagnetic radiation, chemical changes or acoustic emission. Electrical, acoustic, chemical and optical methods of PD measurement are the popularly accepted methods of PD detection in the high voltage (HV) power transformers.

In this context, development of optical fiber based PD sensor can be promising as the optical fibers are made of dielectric material so can be easily placed inside the equipment without any additional insulation arrangements. On the other hand, it has very low transmission loss therefore the measured signal can be transmitted to the sub-station control room without use of any electrical amplification system and it is free from EMI. In this work, a Fiber Bragg Grating (FBG) based optical PD sensor has been developed for online detection of PD within HV power transformer. The shift in wavelength of FBG due to impulsive acoustic pressure generated during PD event has been used for the detection. The performance of the developed FBG based sensor has been validated experimentally with standard electrical (IEC60270) PD measurement system. Experimental results show that the developed sensor is a suitable substitute for conventional PD measuring system and it can be placed inside the apparatus.

Condition Monitoring of High Voltage Transformers using Fiber Bragg Grating Sensor
D. K. Mishra, C. Koley, N. K. Roy

Characterisation of Microstrip patch antenna based UHF sensor for detection of Partial Discharge; Major Prerequisite to overcome the problem due to the insulation breakdown in High Voltage power apparatus is the efficient diagnosis of partial discharge (PD). Many different methods have been proposed by researchers for detection and measurement of PD in past which are based on different outcomes of PD such as Chemical, Acoustic, Electrical, Optical and Electromagnetic (EM) wave radiation. Among these the detection of electromagnetic waves in the Ultra High Frequency (UHF) range could be an efficient method as noncontact type measurement of PD from a longer distance is possible. PD pulses are having life span of several nano-seconds, which can be detected by suitable designed wide bandwidth (BW) UHF sensor.

In this work, a wide BW Microstrip patch antenna has been designed for detection of radiated EM wave in the UHF band due to PD activity within insulator. The proposed antenna is cost effective and having very specific center frequency capable of rejection of surrounding! noise. In this paper the test results obtained from the experiments of characterizing the proposed sensor are presented. The characterization of the sensor has been performed by varying the supply voltage of the insulator and also the distance of the sensor from PD source. The experiment result shows that sensor having good sensitivity and can be used to detect PD from a distance of 15m.

The schematic diagram of combined electrical and optical PD measuring system
Condition Monitoring of High Voltage Transformers using Fiber Bragg Grating Sensor
R.T.Arun Ram Prasath, S.N.Mahato, N.K.Roy, P.Thomas
( A joint venture with CPRI, Banglore)

Power Transformers are one of the most critical component of power system in which mineral oil is used for both insulation and cooling purposes. It acts a insulating medium between solid insulations like kraft paper, pressboard etc. In transformer, dielectric strength of insulation materials mainly depends on the properties of the transformer oil. In this work, a comparative analysis can be made with pure and aged mineral insulating oil using high dielectric permittivity CCTO (CaCu3Ti4O12) nanopowder and its electrical and physical properties are investigated. Nanopowder is added with mineral insulating oil under various particle volume fractions to form nanofluids (NF’s). The electrical and physical properties like breakdown voltage, loss tangent, viscosity, interfacial tension, flash point were measured at room temperature under IS standards. In this work, as an initiative new nanofluids were prepared with high dielectric permittivty CCTO nanopowders dispersed in mineral oil with less than (1%) of particle volume fractions inorder to prevent agglomeration and their electrical and physical properties were studied. The electrical properties like breakdown voltage and loss tangent of nanofluids samples of both pure and aged oil shows enhanced values compared to base oil samples. The physical properties like viscosity, interfacial tension shows satisfactory results but reduction in the properties based on higher concentration of nanopowder. Flash point shows the nature of higher thermal stability in both pure and aged oil samples. Hence, Increased particle volume fraction shows enhanced flash point values.


The schematic diagram of combined electrical and optical PD measuring system
Dr. Nirmal Kumar Roy,
Professor & Dean (Alumni, Outreach Training & Placement),
Department of Electrical Engineering